space-heater
TOBY-H
15-24 KW
Water-based central Heating Pellet Stove
Energy label: A+
Benefits:
TOBY-H 15-24 kW
- Automatic ignition/extinguishing
- Automatic burner cleaning
- Mechanical cleaning of the heat exchanger
- The boiler is equipped with: a circulation pump, a safety valve and an expansion vessel
- High power modulation amplitude
- Durable construction
- Patented burner design
- Possibility to connect a room thermostat
- Energy efficiency class A+
Our boilers in detail
Specifications of TOBY-H
The TOBY H pellet stove with a water circuit is manufactured in accordance with the EN 14785 standard and complies with the provisions of Ecodesign 2015:1189 .
Heat is distributed in two ways: by direct radiation to the environment and to the central heating water circuit.
The circulation pump, expansion tank and safety valve are included in the stove’s package and are installed at the factory. The door is made of cast iron.
The advantage of this product is the original design of the rotating burner (similar to B-Smart – this solution is included in the European register by EUIPO).
The lower part of the burner is made of cast iron.
Ignition, start-up and shutdown are fully automated. Combustion control is optimized using a modulation algorithm that automatically reduces the amount of pellets supplied when the difference between the desired and achieved temperatures decreases.
Pellets are fed from the tank to the boiler using an internal automatic conveyor. From there, the pellets are fed into the combustion chamber, where they freely fall into the designated combustion zone (built-in boiler burner). For safety reasons, the storage and combustion zones are physically separated. A safety thermostat is also installed to protect against ignition of pellets in the tank.
Default version of the product comes with the premium touch-screen display
The boiler controller can be connected to a room thermostat.





| TYPE | TOBY H 15 | TOBY H 20 | TOBY H 24 |
|---|---|---|---|
| Nominal power | 14,3 kW | 20,6 kW | 23,8 kW |
| Total power | 4,3 kW – 14,3 kW | 6,3 kW – 20,6 kW | 7,3 kW – 23,8 kW |
| Power transmitted to the central heating system | 12,2 kW | 17,1 kW | 19,4 kW |
| Max power radiated to the surrounding area | 2,1 kW | 3,5 kW | 4,4 kW |
| Heating area (an estimate to be taken with reserve) | do 100 m² | do 125 m² | do 160 m² |
| Width (mm) | 520 | 580 | 605 |
| Height (mm) | 1155 | 1080 | 1140 |
| Lenght (mm) | 820 | 820 | 935 |
| Flue gas exit height (mm) | 200 | 200 | 220 |
| Flow / Return (inch) | 1“ | 1“ | 1“ |
| Weight (kg) | 230 | 260 | 291 |
| Pellet storage capacity | 20 kg | 22 kg | 25 kg |
| Flue gas opening (mm) | ø80 | ø80 | ø80 |
| Air inlet (mm) | ø50 | ø50 | ø50 |
| Necessary draught | 10,9 Pa | 13,3 Pa | 13,8 Pa |
| Maximum working pressure | 2,5 bar | 2,5 bar | 2,5 bar |
| Water volume (lit) | 19 lit | 29 lit | 38 lit |
| Flue gas exit temperature | <160 ºC | <160 ºC | <160 ºC |
| Energy consumption during start-up | 400 W | 400 W | 400 W |
| Energy consumption at steady-state | 100 W | 100 W | 100 W |
| Electrical network | 220V 50 Hz | 220V 50 Hz | 220V 50 Hz |
| Boiler efficiency | 89,8 % | 90,6 % | 91,2 % |
| CO emissions | 0,02 % | 0,02 % | 0,19 % |